Cua Circuit Breaker 400V
Qhov no yog Air Circuit Breaker 400V. Peb tsim nws rau siab -muaj peev xwm qis-voltage systems. Cov khoom no ua haujlwm nrog 400V AC fais fab kab. Nws muaj lub peev xwm tawg siab thiab zoo heev tam sim no txwv kev ua haujlwm.
Hauj lwm lawm
Siab -Kev Tiv Thaiv Muaj Peev Xwm rau Kev Tshaj Tawm Loj
Qhov no yog Air Circuit Breaker 400V. Peb tsim nws rau siab -muaj peev xwm qis-voltage systems. Cov khoom no ua haujlwm nrog 400V AC fais fab kab. Nws muaj lub peev xwm tawg siab thiab zoo heev tam sim no txwv kev ua haujlwm. Tsis zoo li cov hluav taws xob hluav taws xob me me, cov khoom siv no tswj cov dej ntws loj dua. Nws yog siv rau cov kab xaim loj, tsheb npav txuas, thiab cov khoom siv loj tiv thaiv.
Advanced Arc Extinguishing Technology
Peb Cov Hluav Taws Xob Hluav Taws Xob 400V siv cov thev naus laus zis thev naus laus zis. Nws muaj cov ntaub ntawv tiv tauj zoo. Cov khoom muaj ib tug cais arc chamber thiab arc qhia ntaus ntawv. Thaum muaj kev txhaum tshwm sim, cov khoom no nrawm nrawm rau lub arc thiab tso nws tawm. Qhov no tiv thaiv lub zog hluav taws xob kom zoo. Lub modular tsim ua rau nws yooj yim rau nruab thiab hloov hauv cov khoom faib khoom. Peb tau tsim cov khoom no rau kev saib xyuas yooj yim.

Main Specifications
|
Parameter |
Technical Data |
|
Rated Tam sim no |
63A - 125A |
|
Rated Voltage |
400V AC, 50/60Hz |
|
Number of Poles |
3P, 4P |
|
Trip yam ntxwv |
Hom C, Hom D |
|
Rated Ultimate Short-Circuit Peev Xwm (Icu) |
10kA - 15kA |
|
Rated Service Short-Circuit Peev Xwm (Ics) |
100% Icu |
|
Neeg kho tshuab lub neej |
Ntau tshaj lossis sib npaug rau 20,000 kev ua haujlwm |
|
Hluav taws xob lub neej |
Ntau dua lossis sib npaug rau 8,000 kev ua haujlwm |
|
Kev tiv thaiv qib |
IP20 |
|
Txoj Kev Mounting |
DIN rail mounting |
|
Cov qauv |
IEC 60947-2, GB/T 14048.2 |
Siv nyob rau hauv Factory thiab Commercial Main Panels
Qhov no Cua Circuit Court Breaker 400V yog siv rau pem hauv ntej-kawg tiv thaiv nyob rau hauv qis-voltage systems. Nyob rau hauv factories, nws mus nyob rau hauv lub ntsiab faib txee thiab rhiav panels. Nws tiv thaiv tag nrho cov kab xa tawm. Hauv cov tsev lag luam, cov khoom no tau nruab rau hauv cov thawv loj hauv pem teb. Nws kuj yog siv nyob rau hauv lub hnub ci photovoltaic systems. Peb muab cov kev cai hloov tau yooj yim. Xaiv qhov sib txawv tam sim no los ntawm 63A txog 125A. Xaiv 3P lossis 4P teeb tsa. Peb txhawb hom logo luam ntawv thiab kev hloov kho.
Cim npe nrov: Tuam Tshoj cua Circuit Court breaker 400v manufacturers, lwm tus neeg, Hoobkas
Xa kev nug
Koj Tseem Yuav Zoo Li








