Tuam txhab & Hoobkas
Q: Koj lub Hoobkas tau ua haujlwm ntev npaum li cas?
A: Peb yog lub Hoobkas tsim thiab tsim cov khoom siv hluav taws xob. Peb tau ua haujlwm rau 15 xyoo.
Q: Qhov loj ntawm koj qhov chaw thiab pes tsawg tus neeg ua haujlwm koj ua haujlwm?
A: Peb lub Hoobkas npog thaj tsam ntawm 2,100 square meters thiab muaj 16 mus rau 35 tus neeg ua haujlwm. Peb yuav kho tus naj npawb ntawm cov neeg ua haujlwm tsim khoom raws li kev txiav txim ntau lawm.
Q: Koj puas muaj koj tus kheej R & D pab pawg?
A: Peb muaj peb tus kheej kev tshawb fawb thiab kev tsim kho pab pawg.
Q: Koj puas muaj kev paub ua haujlwm nrog cov npe loj thoob ntiaj teb?
A: Peb muaj kev paub dhau los hauv kev tsim khoom rau qhov zoo -paub hom ABB.
Q: Koj puas ua raws li cov cai hauv ib puag ncig?
A: Peb qhov chaw tsim khoom ua tau raws li Tuam Tshoj txoj kev tiv thaiv ib puag ncig.
Khoom & Customization
Q: Koj puas txhawb OEM / ODM cov kev pabcuam?
A: Peb cov khoom tuaj yeem tsim tau raws li daim ntawv cog lus, raws li daim ntawv tso cai, lossis muag raws li peb lub npe. Kev txiav txim tuaj yeem muab tso rau raws li cov neeg siv khoom xav tau.
Q: Koj puas tuaj yeem tsim raws li peb cov duab kos duab lossis cov qauv?
A: Peb muaj tag nrho cov kev txawj ntse thiab kev txawj ntse los tsim thiab tsim raws li cov duab kos los ntawm cov neeg siv khoom. Peb yeej txaus siab pab koj.
Q: Koj tus MOQ (yam tsawg kawg nkaus Order Quantity) yog dab tsi?
A: Peb qhov kev txiav txim yam tsawg kawg nkaus yog 500 daim. Peb kuj tuaj yeem muab cov qauv txiav txim rau koj sim.
Q: Koj puas tuaj yeem muab tus qauv / qauv ua ntej ntau lawm?
A: Peb kuj tuaj yeem muab cov ntawv sau ua qauv rau koj sim.
Q: Nws siv sijhawm ntev npaum li cas rau kev tsim qauv kev cai?
A: Lub voj voog kev loj hlob ntawm peb cov khoom feem ntau yog nyob ib ncig ntawm 15 mus rau 30 hnub.
Q: Koj puas muab cov qauv dawb?
A: Peb tuaj yeem muab cov ntawv xa mus rau koj qhov kev sim, tab sis tus nqi thauj khoom yuav yog koj lub luag haujlwm.
Q: Kuv puas tuaj yeem muab cov xim sib txawv lossis cov qauv hauv ib qho MOQ?
A: OK
Quality Assurance
Q: Koj tswj cov khoom zoo li cas?
A: Peb lub Hoobkas nruj tswj hwm txhua tus txheej txheem raws li cov txheej txheem tswj hwm hauv qab no.
1. Kev tswj qhov chaw: Kev tshawb fawb thiab kev tsim kho thiab kev tswj xyuas kev nkag mus rau cov neeg siv khoom
● Kev xaiv nruj thiab tswj cov khoom tseem ceeb ntawm cov khoom siv raw (xws li tooj liab qhov chaw, cov nyiaj tiv tauj, cov yas casings, electromagnetic coils, thiab cov khoom siv mus txawv tebchaws) rau cov khoom siv hluav taws xob ncaj qha txiav txim siab cov khoom zoo. Yog li ntawd, yuav tsum tau tsim kom muaj ib tug neeg muab kev faib cais system:
◇ Ua ntej- nkag mus saib xyuas cov kev tsim nyog (tsim ntawv tso cai tsim khoom, daim ntawv pov thawj kev ua haujlwm zoo), kev sim ua qauv, ntawm - chaw kuaj xyuas;
◇ Kev tshuaj xyuas cov khoom siv tsis tu ncua thaum lub sijhawm kev koom tes (xws li cov khoom siv tooj liab, cov nplaim hluav taws kub ntawm cov yas, cov purity ntawm cov nyiaj sib cuag), tsis yog - cov ntaub ntawv ua raws yog ncaj qha xa rov qab;
◇ Tsim cov npe ntawm cov neeg muab khoom tsim nyog, thiab tshem tawm cov neeg xa khoom tsis ruaj khov.
2. Kev Tswj Xyuas Txheej Txheem: Kev ua haujlwm tau zoo nyob rau theem tsim khoom
● Kev tsim qauv ntawm cov kab ntau lawm thiab kev ua yuam kev -cov ntaub ntawv pov thawj tsim cov txheej txheem kev ua haujlwm (SOP), qhia meej meej txog kev ua haujlwm tshwj xeeb rau txhua txoj haujlwm, xws li:
◇ Qhov sib npaug ntawm cov khoom sib dhos, cov kev xav tau ntawm lub zog (xws li lub zog nruj ntawm cov ntsia hlau kom tsis txhob xoob lossis nruj qhov xwm txheej uas ua rau kev sib cuag tsis zoo);
◇ Parameters rau cov txheej txheem xws li vuam thiab txhaj tshuaj molding (kub, sijhawm), los tiv thaiv luv luv Circuit Court thiab plhaub deformation; Nyob rau tib lub sijhawm, qhia txog kev ua yuam kev- cov khoom pov thawj, xws li cov sensors hauv cov kab sib txuas ua ke kom tsis txhob muaj cov khoom ploj lossis cov qauv tsis raug.
● Cov txheej txheem tshuaj xyuas thiab ua ntej -kev tshuaj xyuas
◇ Ua ntej-thov tshuaj xyuas ua ntej txhua batch ntawm kev tsim khoom, lees paub los ntawm tus neeg soj ntsuam zoo tias qhov loj, sib dhos, thiab kev ua tau zoo ntawm thawj- khoom ua tau raws li qhov yuav tsum tau ua, thiab tsuas yog tom qab dhau los tuaj yeem ua tiav ntau lawm;
◇ Thaum lub sij hawm tsim khoom, tus neeg soj ntsuam zoo ua qhov kev tshuaj xyuas tsis tu ncua ntawm txhua tus txheej txheem, xws li tshuaj xyuas qhov sib dhos sib dhos thiab qhov pom tseeb ntawm kev luam ntawv, txheeb xyuas qhov sib txawv thiab hloov kho sai.
3. Core Assurance: Kev Ntsuas Kev Ntsuas thiab Kev Ntsuas
Kev ntsuam xyuas yog tus yuam sij rau kev tswj xyuas qhov zoo ntawm cov hluav taws xob hluav taws xob, npog tag nrho cov theem ntawm cov khoom xa tuaj, ib nrab-cov khoom tiav, thiab cov khoom tiav, muab faib ua cov kev ntsuam xyuas tsis tu ncua thiab hom kev xeem:
● Kev Ntsuas Tsis tu ncua (yuav tsum tau ua rau txhua pawg)
◇ Kev tshuaj xyuas qhov pom thiab qhov loj: Xyuas seb lub casing puas muaj khawb lossis deformation, seb qhov ntev ntawm cov khoom puas yog raws li cov duab kos, thiab yog tias cov cim pom meej thiab ua tiav;
◇ Kev ntsuas hluav taws xob: Ntsuas qhov kub thiab txias, tiv thaiv kev tiv thaiv, rwb thaiv tsev tiv thaiv (kom tiv thaiv kom tsis txhob tawg), dielectric zog (ua haujlwm siab -voltage breakdown) nyob rau hauv qhov ntsuas tam sim no;
◇ Kev ntsuam xyuas tus yam ntxwv: Txheeb xyuas qhov tseeb ntawm kev thauj mus los ntau dhau thiab luv luv - kev mus ncig hauv Circuit Court, xws li thaum lub overload yog 1.3 npaug ntawm qhov ntsuas tam sim no, nws yuav tsum tau mus hauv lub sijhawm; thaum lub sij hawm luv luv, nws yuav tsum tau mus tam sim ntawd kom tsis txhob muaj kab puas tsuaj;
◇ Mechanical life test: Simulate kaw thiab qhib kev khiav hauj lwm (feem ntau yuav tsum tau ntau txhiab mus rau kaum tawm txhiab zaus), kom ntseeg tau tias kev ruaj ntseg ntawm cov khoom siv tshuab.
● Hom Kev Xeem (yuav tsum tau ua rau cov khoom tshiab lossis cov qauv kev hloov pauv) tso cai rau peb lub chaw kuaj mob lossis tus kheej lub chaw kuaj sim los ua qhov kev sim siab heev, kev sim ntsuas kub, ntsuas kev tiv thaiv corrosion, kuaj electromagnetic compatibility, thiab lwm yam, txhawm rau txheeb xyuas qhov kev ua tau zoo ntawm cov khoom nyob rau hauv cov xwm txheej hnyav, ua kom muaj kev ua raws li cov ntawv pov thawj (xws li CCC, UL, CE).
Q: Koj puas muaj cov neeg ua haujlwm tshwj xeeb rau lub luag haujlwm tom qab- kev muag khoom?
A: Peb muaj ib pab neeg ua haujlwm pabcuam uas tuaj yeem pab koj daws txhua yam kev tshaj tawm -muag.
Q: Koj ua ntej- muag, muag, thiab tom qab- cov txheej txheem kev muag khoom yog dab tsi?(你们的售前, 售中和售后服务的流程是怎样的?)
A: 1. Ua ntej-Kev Pabcuam Muag Khoom Muag:
1. Cov Khoom Taw Qhia: Thaum cov neeg siv khoom nug txog cov khoom, peb yuav muab cov ncauj lus kom ntxaws txog cov khoom lag luam, suav nrog cov khoom lag luam, cov khoom siv tsis zoo, daim ntawv thov, thiab lwm yam, los pab cov neeg siv khoom nkag siab zoo txog cov khoom.
2. Kev daws teeb meem Customization: Raws li cov kev xav tau tshwj xeeb ntawm cov neeg siv khoom, peb yuav muab cov kev pabcuam kho tus kheej kom tau raws li lawv cov kev xav tau tshwj xeeb.
3. Kev Pabcuam Kev Pabcuam: Peb yuav muab cov kws tshaj lij kev pabcuam pabcuam los pab cov neeg siv khoom daws teebmeem teebmeem thaum lub sijhawm xaiv khoom thiab siv. lub ntsiab lus.
2. Kev Npaj Pabcuam Thaum Muag:
1. Order Tracking: Peb yuav tsim kom muaj kev soj ntsuam xyuas cov txheej txheem kom sai li sai tau hloov kho cov xwm txheej ntawm cov neeg siv khoom xaj, kom ntseeg tau tias cov neeg siv khoom tuaj yeem taug qab qhov kev nce qib ntawm lawv cov xaj raws sijhawm.
2. Kev cob qhia khoom: Peb yuav muab kev cob qhia kev siv khoom rau cov neeg siv khoom, suav nrog cov txheej txheem kev ua haujlwm ntawm cov khoom, tom qab- cov servers muag, thiab lwm cov ntsiab lus, los pab cov neeg siv khoom siv cov khoom zoo dua.
3. Tom qab-Kev Pabcuam Muag Khoom Muag: Tom qab cov khoom xa tuaj, peb yuav muab sijhawm ib ntus tom qab- kev cog lus rau kev muag khoom, suav nrog kev kho dawb, kev txhawb nqa kev pabcuam, thiab lwm yam kev pabcuam, kom ntseeg tau tias cov neeg siv khoom tuaj yeem siv cov khoom nrog kev thaj yeeb nyab xeeb.
Q: Koj puas lees txais kev tshuaj xyuas thib peb?
A: Peb cov khoom txhawb nqa thib peb -txoj kev tshuaj xyuas tog.
Q: Koj puas ua 100% kev soj ntsuam ua ntej packing?
A: Ua ntej peb cov khoom raug ntim, 100% kev tshuaj ntsuam xyuas yuav tsum tau ua thiab txhua yam khoom yuav raug luam tawm nrog tus lej traceability.
Q: Yuav ua li cas yog tias cov khoom tuaj txog puas?
A: Peb yuav xyuas kom meej tias cov khoom raug xa mus rau lub tuam txhab freight forwarding. Yog tias cov khoom puas vim peb cov khoom zoo, peb yuav rov- xa lawv. Yog tias qhov kev puas tsuaj los ntawm kev thauj mus los, lub tuam txhab xa khoom xa tuaj yuav them nyiaj rau nws thiab rov- xa cov khoom.
Q: Koj puas muab warranty? Yog tias muaj, ntev npaum li cas?
A: Peb muab ib lub sijhawm lav ib - xyoo.
Kev tsim khoom & kev txiav txim
Q: Lub sij hawm xa tuaj rau cov khoom txheem yog dab tsi?
A: Lub voj voog ntau lawm rau peb cov khoom lag luam feem ntau siv sijhawm li 10 txog 20 hnub.
Q: Lub sijhawm khoom xa tuaj rau kev cai -cov khoom tsim yog dab tsi?
A: Cov khoom lag luam customized, raws li cov khoom xav tau, feem ntau siv sijhawm li 30 hnub.
Q: Koj lub peev xwm tsim tau txhua hli yog dab tsi?
A: Peb lub peev xwm tsim tau txhua hli yog 20,000 Circuit Court breakers.
Q: Koj ua li cas kom ntseeg tau ntawm - lub sijhawm xa khoom?
A: Peb muaj cov ntaub ntawv raw khoom txaus, cov cuab yeej tsim khoom thiab cov neeg ua haujlwm tsim khoom. Thaum tau txais kev txiav txim, peb yuav ua ntej - npaj cov neeg ua haujlwm kom ntseeg tau tias cov khoom xa tuaj ua ntej lub sijhawm.
Q: Kuv puas yuav tau txais kev hloov tshiab tsis tu ncua (duab / yeeb yaj kiab) thaum lub sijhawm tsim khoom?
A: Thaum lub sijhawm tsim khoom, peb tuaj yeem muab cov duab thiab yeeb yaj kiab rau koj thaum twg los tau.
Q: Lub sij hawm ua ntej rau kev txiav txim rov qab yog dab tsi?
A: Peb yuav muab qhov tseem ceeb rau kev xa khoom xa rov qab.
Cov nqe lus them nqi & kev lag luam
Q: Cov nqe lus shipping twg koj txhawb nqa (EXW, FOB, DDP)?
A: Peb txhawb nqa EXW thiab FOB kev xa khoom xa tuaj.
Q: Koj lub sijhawm them tus qauv yog dab tsi?
A: Rau peb cov khoom lag luam, yuav tsum tau them 30% ua ntej, ua raws li 70% kev them nyiaj zaum kawg. Rau cov khoom customized, 50% them ua ntej thiab 50% kev them nyiaj zaum kawg yog qhov tsim nyog.
Q: Dab tsi yog koj li kev cai -cov khoom lag luam them nqi?
A: Customized khoom xav tau 50% them ua ntej thiab 50% tshuav nyiaj li cas.
Q: Koj puas muab cov luv nqi rau kev txiav txim loj loj?
A: Yog tias koj tso qhov kev txiav txim loj, peb yuav muab koj tus nqi luv nqi zoo tshaj plaws rau peb cov khoom.
Q: Koj puas txais cov txiaj ntsig dab tsi (USD, EUR, GBP, thiab lwm yam)?
A: USD, RMB
Q: Cov khoom ntim li cas rau kev xa khoom thoob ntiaj teb?
A: Raws li koj qhov kev thov, peb yuav ntim thiab xa koj cov khoom. Koj tuaj yeem muab cov thawv ntim khoom, lossis peb kuj tuaj yeem tswj kev yuav cov thawv ntim khoom rau koj.
