Xov xwm
-
20
Feb-2026
Txoj Cai Ua Haujlwm Ntawm Cov Hluav Taws Xob Hluav Taws Xob Hluav Taws Xob Hl...Qhov seem tiv thaiv tam sim no muaj nuj nqi ntawm lub tshuab hluav taws xob me me (RCCB) yog raws li kev tshawb pom ntawm qhov seem tam sim no los ntawm xoom-ib ntu tam sim no transformer.
-
19
Feb-2026
Lub ntsiab lus txhais ntawm Miniature Residual Current Circuit BreakerMCB (Miniature Circuit Breaker) yog lub tshuab hluav taws xob me me uas siv rau kev tshaj tawm thiab luv luv - tiv thaiv Circuit Court.
-
18
Feb-2026
Kev xaiv ntawm Miniature Circuit BreakersQhov ntsuas voltage thiab tam sim no ntawm Circuit Court breaker yuav tsum siab dua los yog sib npaug rau qhov kev khiav hauj lwm voltage thiab tam sim no ntawm cov khoom siv kab;
-
17
Feb-2026
Nta ntawm Miniature Circuit BreakersSiab ntsuas luv luv- lub peev xwm tawg, nrog qee qhov ntsuas tam sim no tshaj 10kA.
-
16
Feb-2026
Parameters ntawm Miniature Circuit BreakersRated ua haujlwm voltage (Ue): AC 230V / 400V (1P), 400V (2P, 3P, 4P).
-
15
Feb-2026
Taw qhia rau Miniature Circuit BreakersMiniature Circuit Breakers (MCBs), tseem hu ua micro circuit breakers, yog tsim rau overload thiab luv luv - tiv thaiv Circuit Court ntawm AC 50/60Hz kab nrog cov ntsuas hluav taws xob ntawm 230/40...
-
14
Feb-2026
Kev khiav hauj lwm thiab kev saib xyuas ntawm Residual tam sim no Circuit Bre...Kev teeb tsa ntawm cov khoom siv tam sim no (RCD) yuav tsum ua raws li cov khw muag khoom phau ntawv.
-
13
Feb-2026
Rated tam sim no ntawm Residual Current Circuit BreakerKev xaiv raug thiab tsim nyog ntawm qhov ntsuas kev ua haujlwm tam sim no ntawm cov khoom siv tam sim no (RCD) yog qhov tseem ceeb. Ua ntej, RCD yuav tsum xaiv ua haujlwm thaum muaj hluav taws xob ...
-
12
Feb-2026
Xaiv Cov Ntsiab Cai Ntawm Cov Hluav Taws Xob Hluav Taws Xob Hluav Taws XobTxhawm rau kom ua raws li kev siv cov khoom seem tam sim no (RCDs), lub xeev tau tshaj tawm cov txheej txheem thiab cov cai, suav nrog "Cov Cai Tswj Xyuas Kev Nyab Xeeb ntawm Cov Khoom Siv Hluav Ta...
-
11
Feb-2026
Qhov sib txawv ntawm Kev Siv Cov Hluav Taws Xob Hluav Taws Xob Hluav Taws Xob...Cov cuab yeej siv tam sim no (RCDs) raug teeb tsa ntawm ceg hluav taws xob hluav taws xob, thaum cov khoom siv hluav taws xob seem (RCDs) raug teeb tsa ntawm txhua lub davhlau ya nyob twg, ua rau l...
-
10
Feb-2026
Txoj Cai Ua Haujlwm Ntawm Cov Hluav Taws Xob Hluav Taws Xob Hluav Taws XobUa ntej nkag siab txog lub ntsiab lus tseem ceeb ntawm kev tiv thaiv hluav taws xob, nws yuav tsum nkag siab tias hluav taws xob poob siab yog dab tsi.
-
09
Feb-2026
Nta ntawm Residual Current Circuit BreakersUa ntej, thaum daim phiaj hluav taws xob yog qhov tseeb, cov khoom siv tam sim no (RCD) yuav ua haujlwm ib txwm. Nyob rau hauv cov kev ua haujlwm ib txwm muaj, feem ntau ntawm kev ua haujlwm yog ts...